INSTRUCTION TO PERFORM SUPERHEAT/SUBCOOLING,DUCT SIZING AND PRESSURE SETTINGS
|
|
SUPERHEAT FUNCTION |
|
1. PRESS WET BULB KEY
|
Enter wet bulb reading on 0-9 keypad
|
|
2. PRESS DRY BULB KEY
|
Enter indoor dry bulb reading on 0-9 keypad
|
|
3. PRESS OUTDOOR AMBIENT KEY KEY
|
Enter outdoor ambient temperature on 0-9 keypad
|
|
4. PRESS SUPERHEAT KEY |
Readout displays targeted superheat in degrees Fahrenheit
|
|
1. PRESS REFRIGERANT KEY |
Enter 3 digit # followed by A, B, or C (if needed) on 0-9 keypad
|
|
2. PRESS SUPERHEAT KEY |
Enter targeted superheat on 0-9 keypad or desired superheat value
|
|
3. PRESS PRESSURE KEY |
Enter suction line pressure reading on 0-9 keypad
|
|
4. PRESS LINE TEMPERATURE KEY |
Readout displays required suction line temperature in degrees Fahrenheit
|
|
Add or Substract refrigerent charge if required
|
|
SUBCOOLING FUNCTION |
|
1. PRESS REFRIGERANT KEY |
Enter refrigerant # followed by A, B, or C (if needed) on
0-9 keypad
|
|
2. PRESS SUBCOOLING KEY |
Enter required subcooling on 0-9 keypad
|
|
3. PRESS PRESSURE KEY |
Enter liquid line pressure reading on 0-9 keypad
|
|
4. PRESS LINE TEMPERATURE KEY
|
LCD displays required liquid line temperature in degrees
Fahrenheit Adjust refrigerant charge if required
|
|
ACTUAL SYSTEM SUBCOOLING FUNCTION
|
|
1. PRESS REFRIGERANT KEY |
Enter refrigerant # followed by A, B, or C (if needed) on
0-9 key pad |
|
2. PRESS PRESSURE KEY |
Enter high side pressure reading on 0-9 key pad |
|
3. PRESS LINE TEMPERATURE KEY |
Enter liquid line temperature on 0-9 key pad |
|
4. PRESS SUBCOOLING KEY |
LCD displays actual subcooling in degrees Fahrenheit Adjust
refrigerant charge if required
|
|
ACTUAL SYSTEM SUPERHEAT FUNCTION
|
|
1. PRESS REFRIGERANT KEY |
Enter refrigerant # followed by A, B, or C (if needed) on
0-9 key pad |
|
2. PRESS PRESSURE KEY |
Enter low side pressure reading on 0-9 key pad |
|
3. PRESS LINE TEMPERATURE KEY |
Enter suction line temperature reading on 0-9 reading |
|
4. PRESS SUPERHEAT KEY |
LCD displays actual system superheat in degrees Fahrenheit
Adjust refrigerant charge if required |
|
PRESSURE TEMPERATURE RELATIONSHIP
|
|
1. PRESS REFRIGERANT KEY
|
Enter refrigerant # followed by A, B, or C (if needed) on
0-9 keypad
|
|
2. PRESS PRESSURE KEY |
Enter pressure reading on 0-9 keypad |
|
3. PRESS TEMPERATURE KEY
|
LCD displays temperature in degrees Fahrenheit
|
|
TEMPERATURE PRESSURE RELATIONSHIP |
|
1. PRESS REFRIGERANT KEY
|
Enter refrigerant # followed by A, B, or C (if needed) on
0-9 keypad
|
|
2. PRESS TEMPERATURE KEY
|
Enter temperature reading on 0-9 keypad
|
|
3. PRESS PRESSURE KEY
|
LCD displays pressure in PSIG
|
|
View Details
|
|
DUCT SIZING
|
|
1.PRESS CUBIC FEET PER MINUTE KEY |
Enter cubic feet per minute on 0-9 keypad
|
|
2. PRESS VELOCITY KEY |
Enter velocity on 0-9 keypad
|
|
4. PRESS ROUND DUCT KEY
|
LCD displays required round duct size
|
|
5. PRESS RECTANGULAR DUCT KEY
|
LCD displays required rectangular duct size |
|
6. PRESS EQUIVALENT KEY |
LCD displays equivalent rectangular duct size, Continuing to press equivalent key
will display Other equivalent duct sizes until completed then Not Found is displayed
on LCD
|
|
7. PRESS FLEX DUCT KEY |
LCD displays required flex duct size
|
|
8. PRESS STATIC KEY |
LCD displays corresponding static for round, rectangular,
or flex duct
|
|
TO ATTAIN STATIC FROM CUBIC FEET PER MINUTE AND DUCT SIZE |
|
1. PRESS STATIC KEY |
Enter cubic feet per minute on 0-9 keypad |
|
2. PRESS STATIC KEY |
|
PRESS ROUND, RECTANGULAR, OR FLEX DUCT KEYS |
|
Enter duct size on 0-9 keypad Note:
|
For rectangular duct size enter length x width Using 0-9 keypad and multiply key
|
|
3. PRESS STATIC KEY |
LCD displays corresponding static |
|
View Details
|
|
APPROXIMATE PRESSURE
CONTROL SETTINGS FUNCTION
|
|
1. PRESS REFRIGERANT KEY |
Enter refrigerant # followed by A, B, or C (if needed) on
0-9 keypad
|
|
2. PRESS TEMPERATURE KEY |
Enter maximum temperature desired on 0-9 keypad
|
|
3. PRESS IN KEY |
LCD displays approximate pressure cut in setting
|
|
4. PRESS OUT KEY |
LCD displays approximate pressure cut out setting
|
|
View Details
|
|
LIST OF REFRIGERANTS
|
R409A
|
R13
|
R414B
|
R23
|
R416A
|
R503
|
R404A
|
R508B
|
R507
|
R403B
|
R502
|
R22
|
R402A
|
R407C
|
R402B
|
R417A
|
R408A
|
R410A
|
R11
|
R12
|
R113
|
R134A
|
R123
|
R401A
|
R124
|
R401B
|
R500
|
R114
|
|